ETI0018-1006 DC/AC Power Inverter 1000 VA, 600 Watts 24 VDC In

P/N: ETI0018-1006
DC/AC Power Inverter
1000 VA, 600 Watts
24 VDC In


Selectable 100/110/120* VAC Out

Features

True sinewave output (THD < 3%)
Power On-Off Remote Control
Input & Output fully isolated
Load control cooling fan
Advanced microprocessor
Built-in transfer switch & AC circuit breaker
ROF (Remote Override Function) or ignition lockout function option
Speed up transfer time & synchronized operation with utility AC source
Input polarity reverse/ under voltage/ over voltage protections
Output short circuit/ overload/ over temperature protections
Tri-color indicators display input, output level & failure status
e-13/ CE /FCC approved
Optional 220 /230 /240 VAC Out

Rugged Tactical Inverter

NEMA connectors on Universal Mount Inverter

Model Numbers:
ETI0018-1006
AC Output
AC Voltage
100 / 110 / 120 VAC
Rated Power
600 W
Surge Power
800 W
Waveform
True sinewave (THD < 3)
Frequency
50 / 60 Hz selectable by DIP switch
AC Regulation
+/- 3
Power Factor Allowed
COS -90° ~ COS +90°
Standard Receptacles
HARDWARE
LED Indicator
Input voltage level, output load level & fault status
DC Input
No Load Current Draw
 0.87A  0.43A  0.23A
DC Voltage
 12 VDC   24 VDC  48 VDC
Voltage Range
 10.5~15.0 VDC  21~30 VDC  42~60 VDC
Efficiency (Typ.)
 87.0  90.0  92.0
Fuse
 35A x 2  15A x 24  10A x 2
Circuit Breaker
7 A
Synchronous AC Transfer
Yes
Transfer Switch
10
Transfer Time
4~8 msec
Remote Control Unit
CR8 optional
Protection
Low Battery Alarm
 11 VDC  22 VDC  44 VDC
Low Battery Shutdown
 10.5 VDC  21.0 VDC  42.0 VDC
Over load
Shut off output voltage, re-power on to recover
Over Voltage
 15.3 VDC  30.6 VDC  61.2 VDC
Over Temperature
Shut off output voltage, recovers automatically after temperature goes down 
Output Short
Shut off output voltage, re-power on to recover
Battery Polarity
By fuse opening
Environmental
Working Temperature
0 ~ +40° C
Working Humidity
20 ~ 90 RH non-condensing
Storage Temp. Humidity
-30° C ~ +70° C / -22° F ~ +158° F / 10~95
Standards
Safety Standards
Meets UL458
Isolation Resistance
I/P ~ O/P: 100M Ohms / 500 VDC
EMI & Radiation
Compliance to FCC Class A
EMS Immunity
LVD
e-MARK
Mechanical
Dimensions
393 x 156 x 84 MM (L x W x H)
Packaging
4.0 kgs; 4 sets / 16 kgs / CARTON
Cooling
Load controlled cooling fan

Request a Quote or Product Info.
*(denotes required field)
Contact ETI by mail at:
Energy Technologies, Inc.
219 Park Avenue East
Mansfield, OH 44902-1845
USA

Contact ETI by phone or fax:
Voice: 419-522-4444
FAX: 419-522-4466