with Global AC Power Conditioner ETI’s Tactical Desks are equipped with a power conditioner (and/or UPS), which are easily installed by replacing the drawers. These power drawers are shaped to duplicate the drawer format including the side drawer glides and front locking hasp. By replacing the drawers, we are able to equip new desks quickly or retrofit your pre-existing Tactical Desks with ETI's tactical power equipment. The small top left drawer holds a power conditioner taking either global AC and/or vehicle DC in and outputting 120 VAC, 60 Hz to two GFCI
outlets. These tactical conditioners feature air flow specially designed to work within the confines of a drawer's space and still stay cool. The power rating for these desks is 500 VA though other power levels are available. |
AC OUTPUT | |
Output voltage: | 120 VAC true sinewave std, 220 VAC optional |
Output rating: UPS | 500 VA/300 Watt standard, 1000 VA/600 Watt optional 0.60 power factor standard |
Non-linear load capacity: | Up to 100% non-linear load capability w/o derating |
Output voltage regulation: | ± 3.0%
static regulation of nominal ± 4.0% dynamic (0 to 50% load step) |
Overload surge capacity: | 110% for 10 minutes; 125% for 30 seconds |
Harmonic distortion: | Less than 5.0% into 100% non-linear load |
Output frequency: | 60 Hz ± 1.0% independent of input frequency, 50 Hz optional |
Operational status | Status, load and DC input levels (16) LEDs with dimmer |
AC INPUT | |
Input voltage selection: | Autoranging from nominal 115 VAC to 230 VAC |
Input voltage tolerance: | 85-264 VAC |
Input frequency: | From 47 Hz to 63 Hz |
Input power factor: | Better than 90% typically |
Input/output isolation: | 3000 VAC, >120 dB common mode, <1.0 ma leakage |
Input transient suppression: | Complies with IEEE 587 and UL 1449 |
Input control/protection: | Guarded circuit breaker, front panel |
Input power connection: | AMP CPC, 7 pin, locking |
DC INPUT | |
External DC input: | Nominal 22 to 32 VDC |
External DC control/protection: | Guarded circuit breaker, front panel |
External DC connector: | AMP CPC, 7 pin, locking |
DISTRIBUTION PANEL | |
Output circuits: | Two outputs standard, optional configurations |
Output protection: | GFCI - Ground Fault Circuit Interrupter |
Output receptacles: | NEMA 5-15R, 3 pin, other options |
MECHANICAL | |
Dimensions ( H x D x W ): | 3.75 x14.0 x 12.0 in (95 x 356 x 305 mm) |
Mounting Options: | Desk, Table, Wall, Floor, Portable, Horizontal/Vertical |
Unit
weight: 500 VA GPC 1000 VA GPC |
28 lb. (13 kg) with lift handles front 28 lb. (13 kg) with lift handles front |
Audible noise: | Less than 47 dB @ 5.0 ft., ANSI "A" scale |
Cooling type: | High capacity, positive pressure, forced air |
Cooling air direction: | Rear intake, exhaust to front |
Air intake filter: | Washable metal filter media, others optional |
ENVIRONMENTAL | |
Storage temperature: | -13° to 140° F ambient (-25° to 60° C) |
Operating temperature: | 14° to 122° F ambient ( -10° to 50° C) |
Operating humidity: | 0 to 95% relative humidity (non-condensing) |
Storage elevation: | Up to 40,000 ft (12,192 m), higher optionally |
Operating elevation: | Up to 10,000 ft (3,048 m), higher optionally |
STANDARDS | |
United States: | Meets
UL-1778 standard for UPS equipment, Meets MIL-STDs 1275, 167-1, 454, 810, 1399-300A & MIL-S-901 |
Canada: | CSA C22.2 No. 107 UPS safety requirements |
EMI Protection: | EMI/RFI FCC, Class A; EN55022 |
OPTIONAL ACCESSORIES | |
Emergency Power Off, Cold Start, Alternate I/O Configurations, Dual Source Input, Battery Expansion, Software Interface, 10BaseT Ethernet SNMP/HTTP port |